A long repair list is easier to face when it comes in stages.

Plan your repairs

A sample three-stage plan

Here is how a typical list from an older Torrance chimney might be split. Your own list will differ, but the order of thinking stays the same: fire and exhaust first, water second, comfort third.

  • Stage one, before the next fire: cracked or missing flue tiles, a gap in the liner, a blocked flue, a damaged smoke chamber
  • Stage two, before the next wet season: an open cap, a cracked crown, failed flashing, a wide stack with no cricket
  • Stage three, when it suits you: a gas insert, a top-sealing damper, a new face on the fireplace

Why the flue comes first

A broken clay tile lets heat reach the brick and the wood framing behind it, and lets exhaust leak into the chimney walls. That is a safety problem with every fire. So the flue repair, whether that means replacing a section of tile or running a stainless liner down the whole stack, sits in stage one. Until it is done, the fireplace should not be used.

Relining is the most common stage one job we quote. The liner is sized to whatever will burn in the fireplace: an open wood fire, a wood insert or a gas insert each wants a different diameter. That sizing is why relining has no fixed price on this site; it depends on the height of the flue and what the liner is serving.

Water work, and why it cannot wait forever

Stage two items do not threaten the house today, but they shorten the life of the chimney every winter. Rain through an open top soaks the tile and rusts the damper. A crown with cracks lets water into the top courses of brick. Flashing that has pulled out of its joint sends water into the attic. Fixing these before the rains is cheaper than rebuilding the top of the stack later.

Several of these carry prices on this site and are listed below. A crown repair or flashing on its own depends on what we find on the roof, so we measure and send a written figure.

Stage three is your choice

Once the chimney is safe and dry, anything else is an upgrade. Many owners in stage three turn an open fireplace into a gas insert so it heats the room instead of pulling warm air up the flue. That decision is yours, and the liner fitted in stage one can often be sized for it from the start if you tell us early.

Prices for the usual items in each stage

Most of these repairs carry a range. The steel top is quoted after we measure. Anything not listed is measured and quoted in writing.

Camera scan to build the plan
$385
Tracing and stopping a roofline leak
$550 to $3,300
Water diverter on the uphill side
$440 to $990
Diverter together with all-new step metal
$660 to $1,650
Sealed gas heater set into your firebox
$2,750 to $5,500
Steel top over the flue, fitted
Quoted after we measure

Relining, crown work, dampers, chase covers and flashing alone have no listed range; each gets a written figure once we have measured it.

Questions about staged repairs

Can I use the fireplace between stages?

Only after stage one is done. Stage two and three items do not stop you lighting a fire, but a broken or blocked flue does. The plan marks the line clearly.

Will splitting the work cost more in the end?

Sometimes a little, because each visit has its own setup. Where two items share a roof visit, such as a cap and a cricket, we suggest grouping them. The plan shows where combining saves effort.

Do I need a new camera scan after stage one?

Not usually. If you need proof for a sale or an insurer that the flue repair is done, we can record a short pass of the new liner after the install and add it to your file.

My scan came from another company. Can you plan from it?

We can read it, but we price from what we see. If the recording is clear and recent, a visual check may be enough to confirm it. If not, we run our own scan before quoting the larger items.

What does code actually require?

NFPA 211 and the California building code set the rules for liners, clearances and spark arrestors. Stage one items are the ones that fall short of those rules. Stage two and three items are good practice and upgrades rather than code failures in most cases.

Turn the list into a plan

Bring your findings to the contact page, and we will sort them into stages and price what we can.

Call (323) 529-8023